Outside Diameters and Wall Thicknesses For CPVC 4120, SDR 11 Plastic Pipe As Per ASTM D-2846 | ||||||||
Nominal Size (in.) (mm) |
Outside Diameter, in. (mm) | Wall Thickness, in. (mm) | Pressure Ratting. PSI (Kg.Cm²) | |||||
Avarage | Tolerance | Minimum | Tolerance | 73.4°F (23°C) | 180°F (82°C) | |||
½* (15) | 0.625 (15.9) | ± 0.003 (0.08) | 0.068 (1.73) | +0.020 (0.51) | 400 | (28.1) | 100 | (7.0) |
¾ (20) | 0.875 (22.2) | ± 0.003 (0.08) | 0.080 (2.03) | +0.020 (0.51) | 400 | (28.1) | 100 | (7.0) |
1 (25) | 1.125 (28.6) | ± 0.003 (0.08) | 0.102 (2.59) | +0.020 (0.51) | 400 | (28.1) | 100 | (7.0) |
1¼ (32) | 1.375 (34.9) | ± 0.003 (0.08) | 0.125 (3.18) | +0.020 (0.51) | 400 | (28.1) | 100 | (7.0) |
1½ (40) | 1.625 (41.3) | ± 0.004 (0.10) | 0.148 (3.76) | +0.020 (0.51) | 400 | (28.1) | 100 | (7.0) |
2 (50) | 2.125 (54.0) | ± 0.004 (0.10) | 0.193 (4.90) | +0.023 (0.58) | 400 | (28.1) | 100 | (7.0) |
* For ½” wall thickness minimum is not a function of SDR.